What BS 5839-1 says about building height
The standard's height thresholds reflect the way detector performance changes as ceiling height increases. For smoke and heat detection, the effectiveness of detection depends on the products of combustion reaching the detector. As ceiling height increases, that journey becomes longer and the range of detector technologies permitted by the standard becomes progressively more restricted.
BS 5839-1 recognises this through a series of significant height thresholds. Point smoke detection is generally limited to much lower ceiling heights, while technologies such as optical beam and aspirating smoke detection can extend considerably higher. At 25 metres the available conventional options reduce significantly, with only specific technologies and configurations extending towards 40 metres.
Above 40 metres, the approved technology choices narrow significantly. At this height, most conventional systems are not appropriate as standalone solutions, and designers need to consider technologies that were specifically developed for large-volume, high-ceiling applications.
Where Ciqurix stands in the standards landscape
Ciqurix holds LPCB approval to LPS 1976 for video flame detection. It is the only approved Video Fire Detection solution for applications exceeding 40 metres.
This is not a marginal distinction. For specifiers working on buildings above the 40-metre threshold, LPCB approval to LPS 1976 provides independent third-party assessment of the Video Flame Detection technology, including its detection performance, environmental performance and resistance to false alarm sources. It gives designers an independently approved detection technology to consider where conventional approaches become increasingly restricted.
Increasingly, Ciqurix is referenced in consultant specifications as the named solution for buildings where traditional detection reaches its limits. If you need to demonstrate standards compliance for a high-ceiling project, our team can support the specification process.
How video flame detection works at height
Ciqurix CORE detects the physical characteristics of a flame rather than relying on smoke or heat reaching a ceiling-mounted detector. Detectors process visual and near-infrared images simultaneously, analysing colour, brightness, shape, flicker and movement over time. When enough of these characteristics are present, a fire event is declared.
Detection can occur at distances up to 180 metres. This means detectors can be positioned at height to observe the floor-level risk area — where fires start — without needing smoke or heat to travel upward through a large internal volume first. In tall buildings with complex airflow, ventilation systems or large thermal gradients, this is a meaningful operational difference from ceiling-mounted point detection.
Buildings where this is relevant
The 25-metre threshold applies across a broader range of building types than many specifiers initially expect. High bay warehouses and automated logistics facilities are the most common application, but the same detection challenges arise in aircraft hangars, exhibition halls, university atriums, indoor sports facilities, covered market halls, transport interchanges and architecturally ambitious commercial buildings.
If your project has ceiling heights above 25 metres — and particularly if it approaches or exceeds 40 metres — the detection technology specification warrants careful review against BS 5839-1. Our team can assess the project requirements and advise on the appropriate system design.
Frequently Asked Questions
What does BS 5839-1 say about fire detection above 25 metres?
BS 5839-1 progressively restricts the detector technologies that can be used as ceiling height increases. Point detection reaches its limits considerably below 25 metres, while technologies including optical beam and aspirating smoke detection can extend higher. Above 25 metres the available conventional options reduce significantly, with only particular technologies and configurations extending towards 40 metres.
What detection options are available above 40 metres?
Above 40 metres, most conventional fire detection technologies are not appropriate as standalone solutions under BS 5839-1. Ciqurix is the only LPCB-approved Video Fire Detection solution for applications exceeding 40 metres, holding approval to LPS 1976.
Does Ciqurix comply with BS 5839-1 for high-ceiling buildings?
Ciqurix CORE is a primary fire detection system designed for use within BS 5839-1 compliant fire detection systems. CORE holds LPCB approval to LPS 1976 for Video Flame Detection and can be specified where conventional detection technologies are restricted by the ceiling heights involved. The specific system design depends on the building, application and fire risk assessment.
Can Ciqurix be used alongside existing detection in a tall building?
Yes. In many buildings, video flame detection forms part of a layered detection strategy — for example, covering large open volumes at height while traditional detection remains appropriate in adjacent lower-ceiling areas. System design should be reviewed by a qualified fire detection designer.
How does Ciqurix support the specification process?
Our team can review project plans and advise on detector positioning, coverage areas and system design for high-ceiling applications. We can also provide technical documentation to support consultant specifications.
Contact us to discuss your project.